© Edwards Limited 2015. All rights reserved. Page 39
Edwards and the Edwards logo are trademarks of Edwards Limited.
Installation
M588-00-880 Issue E
To use an inert gas in place of atmospheric air as the DP clean purge gas, first remove the air filter and in its place
connect up the inert gas supply. For pump and booster combinations, the air filter is on the rear pump panel, refer
to Figure 3, item 12. For pump-only systems, refer to Figure 13, item 1. Refer to Section 2.7 for information about
fittings and typical purge gas flows.
A solvent suction pipe is provided with the pump. When only performing a high flow purge procedure the solvent
suction pipe will not be needed. When performing a solvent flush, fit the solvent suction pipe only when ready to
perform the DP clean procedure. For pump and booster combinations, the solvent flush fluid connection is on the
rear pump panel, refer to Figure 3 item 11. For pump-only systems, refer to Figure 13, item 2.
A PDT is required to operate the DP clean high flow purge and solvent flush.
Figure 13 - DP clean assembly for pump only systems
1. Air filter
2. DP clean solvent flush fluid connection
3. Inlet spool
4. Pneumatic valve inlet connection
5. Pneumatic regulator
6. Optional connection to pneumatic valve sensor
7. Pneumatic valve
8. Pneumatic valve electrical connection