Appendix A2
Figure A65 - MicroTIM options menu
A2.14.1 Configuring the channel 2 input
By default, the MCM MicroTIM channel 2 input is configured to control Green Mode/Standby mode for GXS but the
user has the option of setting input 2 to turn the booster on/off, operate the inlet isolation valve, enable PID or
enable the second speed.
From the MicroTIM menu, select Input 2… and then scroll down the menu and press ENTER to select the input of
choice.
Notes: 1. Only one input option can be active at a time.
2. If using Channel 2 to control the booster, the booster will not start unless the dry pump is on. This input
is ignored if the GXS system does not have a booster.
3. The Second Speed input can be used to control the speed of either the dry pump or the booster, this can
be set using the SPEED CONTROL menus, refer to Appendix A2.10.