A2.4.4 Commands menu
Under the Setup menu. Scroll by pressing UP/DOWN keys. Press ENTER to open a sub menu or CANCEL to exit back
to the Setup menu. A security code is needed to enter the Commands menus: 202.
Press the UP/DOWN keys to select the new settings and press ENTER to accept or CANCEL to exit back to the
Commands menu.
A2.4.4.1 Gas valves menu
Scroll by pressing UP/DOWN keys. Press ENTER to open a sub menu or CANCEL to exit back to the Setup menu.
Settings do not appear if they are not fitted.
Press the UP/DOWN keys to select on / off and press ENTER to accept or CANCEL to exit back to the Gas valves menu.
A2.4.5 Set sequences menu
Under the Setup menu. Scroll by pressing UP/DOWN keys. Press ENTER to open a sub menu or CANCEL to exit back
to the Setup menu. A security code is needed to enter the Set sequences menus:202.
Table A6 - Commands menu
Commands menu
Inlet Isolation Valve (Open/Shut)
MB Pump (On/Off)
*
*
The PDT must be in control to perform these functions.
Green Mode
Green Level
Solvent Soak
DP Clean
Gas Valves
PID Autotune
PID (On/Off)
2nd DP Speed
2nd MB Speed
Test Mode (On/Off)
Table A7 - Gas valves menu
Gas valves menu
Set N
2
Seal
Set Gas Ballast
Set Inlet
Table A8 - Set sequences menu
Option Text on PDT line 2
Options on PDT line 2 after pressing Enter (use
up/down arrow to change, enter to select)
Warm up Sequence Warmup options… See Warm up options menu
Booster start options BP Start Options… See Booster Pump Start options menu
Micro TIM options Micro TIM... See Micro TIM menu