© Edwards Limited 2015. All rights reserved. Page 121
Edwards and the Edwards logo are trademarks of Edwards Limited.
Appendix A2
M588-00-880 Issue E
The following menus are used by the PDT to on-process Ramp:
Figure A47 - On-process ramp PDT menu configuration items
On-process Ramp is enabled by setting a ramp delay time greater than zero. This time is the time delay between
pump speed increases. The ramp step size determines the size of each step. Pump speed will not exceed the
maximum allowed pump speed.
A2.9 How to set up DP clean
The DP clean set sequence can be used to clean the dry pump of GXS systems that are fitted with the high flow purge
and solvent flush kit.
Before using DP clean, ensure that the high flow purge and solvent flush kit is set up as described in Section 3.14.
Refer also to Section 4.9.
The DP clean process is run while the dry pump is in Green Mode / standby mode. By default DP Clean runs for 20
minutes with the dry pump running at 80 Hz with no inlet purge.
The following flow chart shows the functional behaviour of dry pump clean: