© Edwards Limited 2015. All rights reserved. Page 11
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
M588-00-880 Issue E
2.5 Electrical data
* The minimum geometric wire gauge for Han
®
K 4/4 is 6mm
2
and minimum AWG size is 8 AWG.
† The minimum geometric wire gauge for Han
®
100A module is 10mm
2
and minimum AWG size is 6 AWG.
Table 7 - Electrical data
Characteristics GXS160
GXS160
/1750
GXS250
GXS250
/2600
GXS450
GXS450
/2600
GXS450
/4200
GXS750
GXS750
/2600
GXS750
/4200
Units
Dry pump motor
rating
7.5 7.5 7.5 7.5 11 11 11 22 22 22 kW
Mechanical
booster motor
rating
- 4.5 - 7.5 - 7.5 7.5 - 7.5 7.5 kW
Current rating
(200 - 230 V
systems)
25 31 31 38 49 65 65 120 140 135 A
Current rating
(380 - 460 V
systems)
11 14 14 20 26 34 34 60 78 74 A
Recommended
branch circuit
fuse UL
(200 - 230 V
systems)
30 40 40 50 60 80 80 150 170 160 A
Recommended
branch circuit
fuse IEC
(200 - 230 V
systems)
25 35 35 35 50 65 65 120 140 135 A
Recommended
branch circuit
fuse UL
(380 - 460 V
systems)
15 20 20 25 30 40 40 75 95 90 A
Recommended
branch circuit
fuse IEC
(380 - 460 V
systems)
15 15 15 20 30 35 35 63 80 75 A
Min cable size
for 200 - 230 V
systems (or
corresponding
AWG size)
6 (8)* 6 (8)* 6 (8)* 10 (8) 10 (6) 16 (4) 16 (4) 35 (2) 50 (1/0) 50 (1/0) mm
2
(AWG)
Min cable size
for 380 - 460 V
systems (or
corresponding
AWG size)
6 (8)* 6 (8)* 6 (8)* 6 (8)* 6 (8)* 10 (6)† 10 (6)† 16 (4) 25 (4) 25 (4) mm
2
(AWG)
Mains connector
for 200 - 230 V
systems
Han
®
K
4/4
Han
®
K
4/4
Han
®
K
4/4
Han
®
K
4/4
Han
®
K
4/4
Han
®
100A
module
Han
®
100A
module
Han
®
200A
module
Han
®
200A
module
Han
®
200A
module
Mains connector
for 380 - 460 V
systems
Han
®
K
4/4
Han
®
K
4/4
Han
®
K
4/4
Han
®
K
4/4
Han
®
K
4/4
Han
®
100A
module
Han
®
100A
module
Han
®
100A
module
Han
®
100A
module
Han
®
100A
module
-