EasyManua.ls Logo

Edwards GXS 160

Edwards GXS 160
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M588-00-880 Issue E
Page 56 © Edwards Limited 2015. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Maintenance
Figure 15 - Location of oil sight glass and fill plug on gearbox
5.4.2 Inspect the connections, pipelines, cables and fittings
pending on the application, inspection and cleaning of the exhaust pipe and any elbows or check valves fitted may
be needed. Contact Edwards for details and training. If the dry pumping system is not relocated for maintenance,
ensure all supplies are locked out and tagged out before starting the following procedure.
1. Remove the enclosure side and top panels.
2. Check that all the connections are secure; tighten any loose connections. Inspect all cables, pipelines, hoses and
connections and check that they are not corroded or damaged and do not leak; repair or replace any pipelines,
hoses and connections that are corroded or damaged, or which leak.
3. Refit the enclosure side and top panels.
5.5 Overhaul
Edwards provides a full range of overhaul options worldwide. Edwards can provide training, tooling and spares to
enable users to overhaul their pumping systems. Contact Edwards for more information.
WARNING
Do not attempt to overhaul the pump without Edwards training and tooling.
1. Oil filler plug
2. Oil sight glass

Table of Contents