Appendix A2
M588-00-880 Issue E
A2.4.5.2 Booster pump start options menu
Scroll by pressing UP/DOWN keys. Press ENTER to open a sub menu or CANCEL to exit back to the Set sequences
menu.
Press the UP/DOWN keys to select the new settings and press ENTER to accept or CANCEL to exit back to the Booster
pump start options menu.
A2.4.5.3 MicroTIM options menu
Scroll by pressing UP/DOWN keys. Press ENTER to open a sub menu or CANCEL to exit back to the Set sequences
menu.
Table A10 - Booster pump start options menu
Option Text on PDT line 2
Options on PDT line 2 after pressing Enter (use
up/down arrow to change, enter to select)
Booster start mode BP Start Mode Select from: Manual
Time Delay
Booster controller if in Time
Delay Mode
BP delay after.. Select from: Dry pump
Inlet isolation valve
Booster start delay BP start delay.. Range 1-200 seconds
*
*
Scroll through the delay time options by pressing the UP/DOWN keys. Press ENTER to accept the new
setting. Press CANCEL to exit back into the Booster pump start options menu.
Table A11 - MicroTIM options menu
Option Text on PDT line 2
Options on PDT line 2 after pressing Enter (use up/down arrow to
change, enter to select)
Set MicroTIM Input 2 Input 2 … Select from:
Green Mode
Booster
Isolation Valve
PID Enable
Second speed control
Set MicroTIM Output 4 Output 4 … Select from:
Isolation Valve
Warning
Booster
N2 Flow
Water Flow
Exhaust Pressure
Control status
On Process State
Semicon Outputs

Table of Contents