A2.4.5.4 DP clean menu
Scroll by pressing UP/DOWN keys. Press ENTER to open a sub menu or CANCEL to exit back to the Set sequences
menu.
Press the UP/DOWN keys to select enable / disable and press ENTER to accept or CANCEL to exit back to the DP
clean menu.
A2.4.5.5 Warn on-process menu
Press the UP/DOWN keys to select enable / disable and press ENTER to accept or CANCEL to exit back to the Set
sequences menu.
A2.4.5.6 On-process ramp menu
Scroll by pressing UP/DOWN keys. Press ENTER to open a sub menu or CANCEL to exit back to the Set sequences
menu.
Scroll through the options by pressing the UP/DOWN keys. Press ENTER to accept the new setting. Press CANCEL to
exit back into the On-process ramp menu.
Table A12 - DP clean options menu
Option Text on PDT line 2
Options on PDT line 2 after pressing Enter (use
up/down arrow to change, enter to select)
Set clean speed Set DP Speed… Range 20 to 110 Hz
*
*
Scroll through the options by pressing the UP/DOWN keys. Press ENTER to accept the new setting. Press
CANCEL to exit back into the DP clean menu.
Clean time Clean Time… Range 10 minutes to 60 minutes
*
Automatically start on entering
Green Mode
Start in Green Mode … Enable/Disable
Inlet purge open during clean
cycle
Inlet Purge… Enable/Disable
Inlet purge time after clean
cycle
Purge Time Range 0 minutes to 60 minutes
*
Allow DP clean when pump is on
process
Allow on Process Enable/Disable
Automatically run DP clean
during shutdown
Auto On Shutdown Enable/Disable
Allow DP clean when pump is on
process
Allow on Process Enable/Disable
Automatically run DP clean
during shutdown
Auto On Shutdown Enable/Disable
Table A13 - On-process ramp options menu
Option Text on PDT line 2
Options on PDT line 2 after pressing Enter (use
up/down arrow to change, enter to select)
Time between speed step
changes
Ramp Time... Range 0 – 3600 seconds in 60 second steps
Size of speed step changes Ramp Step... Range 5 to 110 Hz in Hz steps