© Edwards Limited 2015. All rights reserved. Page 55
Edwards and the Edwards logo are trademarks of Edwards Limited.
Maintenance
M588-00-880 Issue E
To top up the oil levels, all GXS pumping systems require side panels to be removed:
1. Refer to Figures 14 and 15 to locate the oil fill plugs on the top of the end cover and gearbox.
2. Remove the appropriate oil fill plug and carefully top up with oil, refer to Section 2.1 for specification.
3. Keep adding oil until the oil level is in line with the MAX indicator.
4. Refit the oil fill plug.
5. Refit all dry pumping system side panels.
Figure 14 - Location of oil sight glass and fill plug on end cover
1. Oil filler plug
2. Oil sight glass