Installation
M588-00-880 Issue E
Figure 8 - The Harting Han® 100A axial screw module cable-mounted connector
3.6.2 Customer Connection Kit, Combination Low Volts GXS750
Tools and equipment:
No 1 Pozidrive screwdriver
5 mm Hexagonal Allen key bit
Torque driver set to 10 Nm
Torque settings for connector pins
Cable size (mm
2
) Max torque setting (Nm)
10 6
16 6
25 7
35 8
A. Low volt pin configuration
B. High volt pin configuration
C. Coding pin
D. Mounting screw
E. View from cable side: connect Protective Earth into
earth terminal
F. Insert stranded wire
G. 4 mm hex (Allen) key
1. Pin A2 - Phase 2
2. Pin A1 - Phase 1
3. Pin D1 - Not connected
4. Pin D2 - Phase 3