M588-00-880 Issue E
Page 116 © Edwards Limited 2015. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Appendix A2
A2.6 How to configure the pump warm-up options
By default the GXS pump performs an intelligent warm-up cycle to a temperature set point so that the pump is
warm before it is allowed to be on-process. Once the pump reaches the temperature set point it automatically goes
on-process.
If the pump is no longer to be on-process a choice can be made to either stop the pump or put it into Green Mode/
Standby mode.
If the pump is in Green Mode/Standby mode it can either be put on-process or stopped.
It is possible to change the behaviour of the GXS pump using the PDT. The following menus are used by the PDT to
configure warm-up.
Figure A43 - Warm-up PDT menu items
A2.6.1 Lowering the warm-up temperature
Use the warmup setpoint temp menu item and decrease the warm up set point to the desired temperature. The
minimum temperature allowed is 0 °C.
A2.6.2 Disabling warm-up cycle
It may be required for the pump to skip the warm-up cycle and go directly on-process once it has reached full speed.
There are two ways to achieve this:
Enable COLD ONPROCESS
Adjust the WARMUP Setpoint temp set point to below ambient temperature.