Technical data
M588-00-880 Issue E
2Technical data
2.1 General technical data
Table 1 - General technical data
Pump
Characteristics
Body
dimensions
length x
width x
height
*
*
Refer to installation drawings in Appendix A1.
Mass
(excluding
packaging)
Noise
level (at
ultimate
with a
piped
exhaust)
Typical
vibration
level at
inlet
Initial
force to
push the
pump
For dry pumping systems fitted with optional castors; measured in laboratory on level concrete surface.
Refer to Section 3.3 for information relating to exhaust size and length for GXS750 dry pumping systems.
Sustained
force to
push the
pump
Pump
inlet
flange
(bolted)
Exhaust
gas
outlet
Lubricant
volume
Units mm kg dB(A) mm/s kg force kg force litre
GXS160 1092 x 390
x 568
305 < 64 < 1.5 < 20 < 10 ISO63 NW40 0.7
GXS160/
1750
1092 x 390
x 830
475 < 64 < 1.5 < 20 < 10 ISO100 NW40 1.4
GXS250 1092 x 390
x 568
305 < 64 < 1.5 < 20 < 10 ISO63 NW40 0.7
GXS250/
2600
1092 x 390
x 830
515 < 64 < 1.5 < 20 < 10 ISO160 NW40 1.4
GXS450 1186 x 517
x 717
546 < 64 < 1.5 10 5 ISO100 NW50 1.8
GXS450/
2600
1186 x 517
x 1031
760 < 64 < 1.5 16 6 ISO160 NW50 2.4
GXS450/
4200
1186 x 517
x 1031
818 < 64 < 1.5 22 < 10 ISO160 NW50 3.3
GXS750 1622 x 517
x 717
679 < 70 < 1.5 15 5 ISO100 NW50‡ 2.8
GXS750/
2600
1622 x 517
x 1031
918 < 70 < 1.5 22 < 10 ISO160 NW50‡ 3.5
GXS750/
4200
1622 x 517
x 1031
976 < 70 < 1.5 22 < 10 ISO160 NW50‡ 4.3
Table 2 - General technical data
Item Description Rating Units
Operating conditions
Intended use Indoor
Ambient temperature range:
Operating 5 to 40 °C
Storage - 45 to 55 °C
Maximum relative humidity: 80% for temperatures up to 31 °C decreasing
linearly to 50% relative humidity at 40 °C
Maximum operating altitude 2000 m
Pollution degree 2 (IEC 61010)