SCU-1601 Control Unit for Turbomolecular Pump
MT-96E-1B1-0
Page 120
5
SERIAL COMMUNICATION PROTOCOL
5.4.17.2 Second speed selection
The speed setting set as rotational speed in the normal state can be read.
Parameter
Item
Data format
Remark
1
Option function number
16-bits hexadecimal
coded ASCII
0015
hex
2
Second speed selection
16-bits hexadecimal
coded ASCII
0000
hex
: Normal rating speed setting
0001
hex
: Second rating speed setting
Example:
Second speed selection
: 0000
hex
= Normal rating speed setting
Parameter
1
2
ASCII
0
0
1
5
0
0
0
0
HEX
30
30
31
35
30
30
30
30