SCU-1601 Control Unit for Turbomolecular Pump
MT-96E-1B1-0
Page 58
4
OPERATION
4.5 Remote operation
To select remote operation, slide the "MANUAL/REMOTE" changeover switch on the SCU-1601 front
panel to "ON", refer to Figure 12. The "REMOTE" LED illuminates.
4.5.1 Input signal pins
Use input signal pins according to Table 8, Table 9 and Figure 36. Remote input signals are set to the
parallel port in the remote setting and function during REMOTE operation only, except pins for
inputting the ROTATION INHIBIT.
Two abbreviations are used in Table 8, Table 9 and Figure 36:
COM: Common Pin
IN: Input Pin