STP-iS2207 Series Turbomolecular Pump 
 
MT-89E-001-C
Page
63
4
 
Pin  Description 
 
Pins for outputting the ACCELERATION state signal. 
These pins are closed when the STP pump is in acceleration.
 
 
 
Pins for outputting the NORMAL OPERATION state signal. 
When the STP pump is in rated operation, the pins between 
(6)-(19) are closed. 
 
 
 
Pins for outputting the BRAKE state signal. 
These pins are closed when the STP pump is in brake. 
 
 
Pins for outputting the FAILURE signal. 
When an abnormality/error is detected, the pins between 
(8)-(21) are closed, and the pins between (9)-(21) are opened.
 
 
 
Pins for outputting the WARNING signal. 
These pins are closed when the STP pump is WARNING state. 
Refer to Section 7.2, "Safety Functions" for the warning. 
 
 
 
Pins for outputting the parallel port select state signal. 
When the input operation port is set to the parallel port (I/O 
REMOTE), the pins are closed. 
 
Pins for optional signal output. 
In state of the second speed option is "ENABLE", and second 
speed is selected, the pins are closed. 
Table 14 - X2 REMOTE output signal pins 
(5)                                    (18)
ACCELERATION 
N.O OUT 
(7)                                    (20)
BRAKE 
N.O OUT 
(8)   N.O OUT 
 
 
(9)   N.C OUT 
FAILURE 
COM
(21)
(4)                                     (17)
I/O ENABLE 
N.O OUT 
NORMAL 
COM
(19)
WARNING 
COM
(23)
(11)                                     (24)
OPT 
N.O OUT