DL8000 Preset Instruction Manual
E-62 DL8000 Keypad Display Revised February-2016
You can either press EXIT to quit product calibration or STOP to end
the current transaction.
If a transaction is in progress and you press STOP, the transaction ends
and batching status moves to 1 (Select Recipe).
If you have enabled the automatic selection of recipes (parameter
64,0,5), this parameter also disables automatic recipe selection. This
option, if not disabled, prevents the transaction from ending.
Note: Selecting Product Calibration disables the automatic recipe
selection feature. The program does not automatically restore
this feature. You must manually reset it if required.
Check
Weights & Measures
Switch
Once the transaction has ended and batching status [63,0,9] is Select
Recipe (1), the system then checks the state of the Weights & Measures
switch [62,0,148]. If the switch is closed (status is 1), the following
message displays:
14/03/12 12:26:02
EXIT to Quit
WM Switch is Closed
Pls open the Switch
And press ENTER
This screen displays until you either open the W&M switch or exit
product calibration.
Select
Delivery Type
If the W&M switch is open, the process moves to the selection of the
product delivery type [63,0,29].
14/03/12 12:26:02
Sel Delivery Type
ENTER to Continue
Exit to Quit
(SELECT)
Gross
Press SELECT to choose a preset delivery type (Gross, Standard, or
Mass) and then press ENTER to move to the next screen in the process.
(Press EXIT to redisplay the Prover Selection screen.)
Select
Product
After selecting a delivery type, you then select the product (or
component) to be calibrated. The available components are defined in
the Number of Components in System parameter [63,0,21].