DL8000 Preset Instruction Manual
Revised February-2016 DL8000 Keypad Display E-65
14/03/12 12:26:02
Flowrate 1
Flowrate 2
Flowrate 3
Flowrate 4
UP | DOWN
ENTER to Continue
0.000000
0.000000
0.000000
0.000000
The system can display a maximum of four flow rates on one page. If
you have defined more than four flow rates, they appear on the next and
subsequent pages (for a maximum of three pages).
Use the and keys to move between flow rates, changing the values
as necessary. For this example, we defined four flowrates:
14/03/12 12:26:02
Flowrate 1
Flowrate 2
Flowrate 3
Flowrate 4
UP | DOWN
ENTER to Continue
100.000000
200.000000
300.000000
400.000000
Once you define the values, press ENTER to continue to the next
screen. (Press EXIT to redisplay the Max FR Set points screen.)
Note: When you press ENTER, the system verifies that all flow rates
are in ascending order (that is, flow rate 2 is greater than flow
rate 1, flow rate 3 is greater than flow rate 2, and so on) and that
no flow rate is zero. If the system detects an error, it displays the
message Flowrate Cfg Error .
After you define the flow rate set points, press ENTER to continue. The
preset adds the flow rates to the appropriate TLPs ([69,X,76] to
[69,X,98]) and displays a screen summarizing the selected
configuration:
14/03/12 12:26:02
Component
Meter
Sel MAX FR Setpoint
Max Flowrate
Current MF
ENTER to Continue
EXIT To Go Back
Component 1
Meter 1
Flowrate 5
500.000000
0.999063
Press EXIT to redisplay the flowrate entry screen.