DL8000 Preset Instruction Manual
Revised February-2016 DL8000 Keypad Display E-65
Flowrate 1
Flowrate 2
Flowrate 3
Flowrate 4
UP | DOWN
0.000000
0.000000
0.000000
0.000000
The system can display a maximum of four flow rates on one page. If
you have defined more than four flow rates, they appear on the next and
subsequent pages (for a maximum of three pages).
Use the and keys to move between flow rates, changing the values
as necessary. For this example, we defined four flowrates:
Flowrate 1
Flowrate 2
Flowrate 3
Flowrate 4
UP | DOWN
100.000000
200.000000
300.000000
400.000000
Once you define the values, press ENTER to continue to the next
screen. (Press EXIT to redisplay the Max FR Set points screen.)
Note: When you press ENTER, the system verifies that all flow rates
are in ascending order (that is, flow rate 2 is greater than flow
rate 1, flow rate 3 is greater than flow rate 2, and so on) and that
no flow rate is zero. If the system detects an error, it displays the
message Flowrate Cfg Error .
After you define the flow rate set points, press ENTER to continue. The
preset adds the flow rates to the appropriate TLPs ([69,X,76] to
[69,X,98]) and displays a screen summarizing the selected
configuration:
Component
Meter
Sel MAX FR Setpoint
Max Flowrate
Current MF
ENTER to Continue
Component 1
Meter 1
Flowrate 5
500.000000
0.999063
Press EXIT to redisplay the flowrate entry screen.