DL8000 Preset Instruction Manual
Revised February-2016 DL8000 Keypad Display E-67
If the system finds any problems, displays an error message:
14/03/12 12:26:02
EXIT To Go Back
Flowrate Cfg Error
To resolve any configuration errors, press EXIT to return to the
previous screen and re-define the flow rates.
When the system verifies the configuration, it updates all values and
displays a summary screen:
14/03/12 12:26:02
Component
Meter
Sel MAX FR SetPoint
Current MF
ENTER To Continue
EXIT To Go Back
Component 1
Meter 1
Flowrate 5
500.000000
1.000000
To change any value, press EXIT to redisplay the set flow rate set
points screen.
If you are satisfied with the summary display of values, press ENTER.
The preset configures recipe 1 using the identified components 100% of
the recipe. For example, if you select component 1, the system
configures recipe 1 as:
CMP 1 = 100% [68,0,1]
CMP 2 = 0 [68,0,2]
CMP3 = 0 [68,0,3]
CMP4 = 0 [68,0,4]
Seq. or Lo proportion = 1 [68,0,17]
Note: The Seq. or Lo proportion depends on the number of the
selected component. If you select component 2, the Seq. or
Lo Proportion value becomes 2.
Additionally, the system:
Sets Unit Type [63,0,12] as 0 (“Seq. Auto”)
Sets No. of batches per transaction [63,0,126] to 0 (zero)
Sets Disable the Flush [68,0,5] to 0
Sets No. of additives [63,0,100] to 0
Sets No. of data items [63,0,186] to 0
Sets the number of info parameters [63,0,228] to 0
Sets the number of data items [63,0,186] to 0