37
3.6.3.1 Record Detection Activate
This feature makes the whole setting of motion setup is efficacious and system will log
the motion triggered event even the DVR under the “Time Recording” mode.
Enable: Activates the whole setting of motion setup
Disable: Deactivates the whole setting of motion setup
NOTE Remember to specify the area you would like monitor using the
“Motion Area Setup” screen. Click on a particular channel you would
like to set and then click on Motion Area Setup to define the
particular area you would like to monitor.
3.6.3.2 Motion Mode
Choose any of the following settings to adjust the motion sensitivity parameter:
Sensitive OFF: No sensitivity
Sensitive Low: Low sensitivity level
Sensitive Normal: Normal sensitivity level
Sensitive High: High sensitivity level
Sensitive Highest: The highest sensitivity level
3.6.3.3 Record Time
Set the recording time when the Motion Mode is triggered.
The recording time as 5sec, 10sec, 15sec, 20sec, 25sec, 30sec, 45sec, 60sec, 90sec,
120sec, 150sec or 180sec.
3.6.3.4 Alarm Mode
Select the alarm mode when Motion Mode is triggered.
Mute: No beep whatever motion is detected or not.
Buzzer-Short: Beep shortly by buzzer on main board.
Buzzer-Long: Beep long by buzzer on main board.
Alarm-Short: Short sound coming from the alarm.
Alarm-Long: Prolonged sound coming from the alarm.
3.6.3.5 Alarm Time
The Alarm Time is the duration of the beep and may be set to: “Nonstop”(no stop), 5sec,
10sec, 15sec, 20sec, 25sec, 30sec, 35sec, 40sec, 45sec, 50sec, 55sec or 60sec.