PROline Promag 53 10 Technical data
Endress+Hauser 125
Process
Medium temperature
range
The permissible fluid temperature depends on the lining of the measuring tube:
Promag W
32 to 176 °F (0 to +80 °C) for hard rubber (2.5" - 78" / DN 65 - 2000)
4 to 158 °F (–20 to +70 °C) for polyurethane (1" - 78" / DN 25 - 2000)
Promag P
40 to 266 °F (–40 to +130 °C) for PTFE (1/2" - 24" / DN 15 - 600), for restrictions → refer
to diagrams
4 to 356 °F (–20 to +180 °C) for PFA (1" - 8" / DN 25 - 200), for restrictions → refer to
diagrams
Fig. 59: Compact version Promag P (with PFA or PTFE lining)
T
A
= ambient temperature, T
F
= fluid temperature, HT = high-temperature version, with insulation
Fig. 60: Remote version Promag P (with PFA or PTFE lining)
T
A
= ambient temperature, T
F
= fluid temperature, HT = high-temperature version, with insulation
6-5xPxxxxx-05-xx-xx-xx-000aeF06-xxPxxxxx-05-xx-xx-xx-000ae