Diagnostics and troubleshooting Proline Promag L 400 PROFIBUS DP
104 Endress+Hauser
The user is in the diagnostic message.
1. Press  ( symbol).
The Diagnostic list submenu opens.
2. Select the desired diagnostic event with  or  and press  .
The message for the remedial measures for the selected diagnostic event opens.
3. Press  +  simultaneously.
The message for the remedial measures closes.
The user is in the Diagnostics menu at an entry for a diagnostics event, e.g. in the
Diagnostic list submenu or the Previous diagnostics parameter.
1. Press .
The message for the remedial measures for the selected diagnostic event opens.
2. Press  +  simultaneously.
The message for the remedial measures closes.
12.4 Diagnostic information in the Web browser
12.4.1 Diagnostic options
Any faults detected by the measuring device are displayed in the Web browser on the
home page once the user has logged on.
1
3
2
A0017759-EN
1
2
3
Status area with status signal
Diagnostic information (→  103)
Remedial measures with Service ID
Furthermore, diagnostic events that have occurred can be viewed in the Diagnostics
menu:
Via parameters (→  111)
Via submenus (→  111)
Status signals
The status signals provide information on the state and reliability of the device by
categorizing the cause of the diagnostic information (diagnostic event).
Symbol Meaning
A0017271
Failure
A device error has occurred. The measured value is no longer valid.
A0017278
Function check
The device is in service mode (e.g. during a simulation).