Operation Proline Promag L 400 PROFIBUS DP
94 Endress+Hauser
11 Operation
11.1 Reading device locking status
The write protection types that are currently active can be determined using the Locking
status parameter.
Navigation
"Operation" menu → Locking status
Function scope of "Locking status" parameter
Options Description
None The access status displayed in "Access status display" parameter applies
(→  59). Only appears on local display.
Hardware locked The DIP switch for hardware locking is activated on the main electronics module.
This prevents write access to the parameters (→  92).
Temporarily locked Due to internal processing in the device (e.g. up-/downloading of data, reset), write
access to the parameters is blocked for a short time. Once the internal processing
has been completed, the parameters can be changed once again.
11.2 Adjusting the operating language
Information (→  75)
For information on the operating languages supported by the measuring device
(→  144)
11.3 Configuring the display
Basic settings for local display (→  78)
Advanced settings for local display (→  87)
11.4 Reading measured values
Using the Measured values submenu , it is possible to read all the measured values.
"Diagnostics" menu → Measured values
11.4.1 Process variables
The Process variables submenu contains all the parameters needed to display the current
measured values for every process variable.
Navigation
"Diagnostics" menu → Measured values → Process variables
Structure of the submenu
Process variables
Volume flow
Mass flow
Conductivity