Technical data Proline Promag L 400 PROFIBUS DP
140 Endress+Hauser
Materials Transmitter housing
Order Code for "Housing"
Compact version, standard:
Option A: aluminum, AlSi10Mg, coated
Option M: polycarbonate plastic
Compact version, inclined:
Option Q: polycarbonate plastic
Option R: aluminum, AlSi10Mg, coated
Remote version (wall-mount housing):
Option N: polycarbonate plastic
Option P: aluminum, AlSi10Mg, coated
Window material
Transmitter housing material Window material
Polycarbonate plastic Plastic
Aluminum, AlSi10Mg, coated Glass
Cable entries/cable glands
1
2
3
A0020640
 36 Possible cable entries/cable glands
1 Cable entry in transmitter housing, wall-mount housing or connection housing with internal thread M20 x
1.5
2 Cable gland M20 x 1.5
3 Adapter for cable entry with internal thread G ½" or NPT ½"
Compact and remote versions and sensor connection housing
Cable entry/cable gland Material
Cable gland M20 × 1.5 Plastic
Remote version: cable gland M20 × 1.5
Option CK "IP68, Type 6P, waterproof"
Option of reinforced connecting cable
Sensor connection housing:
Nickel-plated brass
Transmitter wall-mount housing:
Plastic
Adapter for cable entry with internal thread G ½" or
NPT ½"
Nickel-plated brass
Connecting cable for remote version
Electrode and coil current cable
Standard cable: PVC cable with copper shield
Reinforced cable: PVC cable with copper shield and additional steel wire braided jacket