Port Broadcast Suppression Configuration Screen
WebView Local Management Tasks 3-55
Screen Element Descriptions
Refer to Table 3-29 for a functional description of each screen element.
Table 3-29 Port Broadcast Suppression Configuration Screen Element Descriptions
Use this field To
Port See the port number associated with the displayed status information.
Broadcast
Suppression
Enable or Disable Broadcast Suppression per port.
Threshold (pps)
(1-1488100)
Set the broadcast suppression limit in packets per second on one or
more ports. This sets a threshold on the broadcast traffic that is
received and thus switched out to other ports.
Note: the maximum value of 1488100 pps is for a Gigabit Ethernet
Port