Functions 11. EMERGENCY
RC700 Series Rev.3 141
Example 2 External safety relay typical application
External
safety relay
External +24V
GND
External +24V
Fuse *
External
+24V
Emergency
Stop switch
Terminal block
External
+24V
GND
External
+24V
GND
External
+24V
GND
* Fuse
For the protection of the emergency stop circuit, the fuse’s capacity should be as
follows:
- Meets the capacity of the external
- 0.4A or less