100i / 200i / 300i / 400i
Manual PN: 0560956430 INSTALLATION 51
2 - Wire and 4 - Wire settings
When used with the Vision T5™ CNC, plug should be in the 2 wire (2W) position shown below.
For other CNC controls using 4 wire communication, place the jumper in the 4W position.
Art # 12322
3.16 Height Control Connections
The terminal strip provides connections to negative Arc Volts (Torch or electrode), Tip Volts (Pilot) and Work. These are for a
height control that requires connection to the full non-divided arc voltage. Also available on the terminal strip are 120VAC and 24
VAC. The allowable current draw is 100ma @ 120VAC and 1Amp @ 24 VAC.
Art # A-11900
24 VAC
@ 1A
TB4
1 2 3 4 5 6 7
120 VAC
@ 100 ma.
Work
Tip Volts
(Pilot)
Arc Volts
(Torch)
Art # A-11954
NOTE!
There are holes added in the rear panel for customer wiring. This, rather than the one in the CCM will be
the preferred place for customer added wiring (and strain relief) for connections to height controls, etc.
.

Table of Contents