52 INSTALLATION Manual PN: 0560956430
3.17 Gas Selection Console Installation
The Gas Selection Console must be installed in a suitable location where it is easily accessible to the system operator. The unit
must be mounted to a flat horizontal surface. If the Module is mounted to any support subject to vibration or motion, the installer
must fasten the module to the support securely.
The Module should be located as far away as possible from the Arc Starter due to possible electromagnetic interference. It is ac-
ceptable to locate the control cable in the same track as the cables from the Arc Starter and away from torch leads.
The Module includes feet which lift the bottom panel of the mounting surface. Louvers on the back panel of the module must
remain unblocked, for the free passage of ventilating air.
Mounting Dimensions
5.00 in
[127.0 mm]
7.08 in
[179.8 mm]
12.18 in
[309.4 mm]
11.44 in
[290.6 mm]
.30 in
[7.62 mm]
DMC-3000 Top
13.60 in
[345.6 mm]
DMC-3000 Profile
Art # A-09459
Preparation
1. Remove the screws securing the Cover Panel to the Module.
Gas Selection Cosole - Top View