EasyManua.ls Logo

EWM PHOENIX 421 EXPERT forceArc - M3.70 Wire Feed Unit Control

EWM PHOENIX 421 EXPERT forceArc
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functional characteristics
Machine control – Operating elements
28 Item No.: 099-004833-EWM01
5.1.2 M3.70 wire feed unit control
M 3.70
sec
sec
SP2
SP1
sec
sec
sec
HOLD
AMP
VOLT
PROG
sec
DYN
Super-
puls
sec
sec
SP3
S
EXPERT
m/min
DYN
- +
6
7
4
3
2
1
5
9
8
Figure 5-2
Item Symbol Description 0
“Parameter selection ” (left)
AMP
Welding current (nominal, actual and hold values)
Material thickness (nominal value)
Wire speed (actual, nominal and hold values)
1
HOLD
AMP
HOLD
After each completed welding process, the last parameter values
used for the welding process are shown on the display in the main
program; the signal light is on
2
LCD display, 3-digit (left)
Display of the parameters and values: Welding current, material thickness, wire speed,
hold values
3
m/min
"Wire speed / welding parameter setting" rotary dial
Infinitely adjustable setting of the wire speed from 0.5m/min to 24m/min (HS: 30m/min)
(welding performance, one-dial operation)
"Select operating mode" button
Non-latched
Latched
Non-latched special (LED green) / MIG spots (LED red)
4
Special latched
"Arc characteristics, choke effect" button
Arc harder and narrower
5
DYN
- +
Arc softer and wider
6
"Arc length correction / program number" rotary dial
Arc length correction from -9.9 V to +9.9 V
Setting the program number 0-15 (not possible if accessory components such as
program torches is connected)

Table of Contents