Functional characteristics
Advanced functions on the wire feed unit control
94 Item No.: 099-004833-EWM01
The number of programs (P
An
) corresponds to the cycle number specified under N cycle.
1st cycle
Press and hold torch trigger.
Shielding gas is expelled (gas pre-flows).
Wire feed motor runs at "creep speed".
Arc ignites after the wire electrode makes contact with the workpiece, welding current is flowing (start
program P
START
from P
A1
)
2nd cycle
Release torch trigger.
Slope to main program P
A1
.
The slope to main program P
A1
is given at the earliest after the set time t
START
elapses and at the
latest when the torch trigger is released. Tapping (pressing briefly and releasing within 0.3 sec)
can switch to other programs. Programs P
A1
to P
A9
are possible.
3rd cycle
Press and hold torch trigger.
Slope to end program P
END
from P
AN
. The program can be stopped at any time by pressing the torch
trigger longer than 0.3 sec. P
END
from P
AN
is then executed.
4th cycle
Release torch trigger.
WF motor stops.
Arc is extinguished after the pre-selected wire burn-back time elapses.
Gas post-flow time elapses.