Test Setup - Test Configurator, Timer, and System
178 MAX-800 Series
Signal - Signal Configuration (SONET/SDH)
REI-L/MS-REI Computation Method (OC-192/STM-64 only): Allows
selecting the default method used to calculate the REI-L/MS-REI error
for OC-192 and STM-64 signals. Choices are M1 Only and both M0 and
M1. The default setting is M1 only.
STS/AU and VT/TU Mappings
Timeslot/Number
Timeslot (SONET) allows the selection of the STS timeslot number.
Refer to SONET Numbering Convention on page 461 for more
information.
Number (SDH) allows the selection of the AU channel number. Refer
to SDH Numbering Convention on page 462 for more information.
TCM check box when selected (cleared by default) allows Tandem
Connection Monitoring (TCM).
TC-UNEQ-P / TC-UNEQ-V / HPTC-UNEQ / LPTC-UNEQ check boxes
when selected (cleared by default) allows the monitoring of the
corresponding Tandem Connection - Unequipped alarm. Only
available when the TCM check box is selected.
Overwrite Fixed Stuff (STS-1 only) check box when selected (default)
fills up the bytes of the STS-1 SPE’s columns 30 and 59 with the
selected pattern from the tab BERT and Unframed BERT on page 78.
Background allows the selection of the high order path background
traffic: AIS, Equipped (PRBS23) - (default), or Unequipped.

Table of Contents