Test Setup - Test Configurator, Timer, and System
MaxTester 151
Services - Global
Services - Global
From the Test menu, tap Setup, Test Configurator, tap on the services
block, the Global tab, and on the General button.
General Button
The following parameters are displayed and configurable per service.
Check boxes:
The first check box (top-left) allows enabling sequentially
service(s) within the limit of the link capacity when the Service
Performance Test is enabled or enabling all services when the
Service Performance Test is disabled.
The check boxes next to the service numbers allow enabling each
service individually.
When the Service Performance Test is enabled, up to 10 services
can be enabled one after the other, as long as the Total TX Rate
(bandwidth) is not reached (Committed). For example, if the first
service is using the full bandwidth available, then no other service
can be enabled. If the first enabled service uses half bandwidth,
then at least another service can be enabled using up to half
bandwidth. Thus, to enable a second service, first set the CIR value
within the non-used bandwidth (Available), then enable it.
When the Service Performance Test is disabled, up to 10 services
can be enabled one after the other; the total TX rate is not limited.
Service Name indicates the name of each service. Tap on the Service
Name button to modify the name of each service. See Services - Profile
on page 154
for more information.
Direction, available with Dual Test Set or Dual Port topology,
indicates respectively results for local (L) and remote (R) directions, or
for both port directions.