Test Results
278 MAX-800 Series
Streams - Frame Loss / Out-of-Sequence
Streams - Frame Loss / Out-of-Sequence
From the Test menu, tap Results, Streams, and the Frame Loss /
Out-Of-Sequence tab.
Note: For Dual Port topology select the port to be displayed.
Stream indicates the stream identification number.
Thresholds button allows setting the pass/fail thresholds (refer to QoS
Metrics on page 190).
Frame Loss: See QoS Metrics on page 237.
Out-Of-Sequence: See QoS Metrics on page 237.
Streams - Jitter
From the Test menu, tap Results, Streams, and the Jitter tab.
Note: For Dual Port topology select the port to be displayed.
Stream: Indicates the stream identification number.
Jitter (ms) is measured for each stream on all valid frames
(in-sequence frames, valid Jitter tag, and no FCS error) received.
Current, Average, Minimum, Maximum, and Estimate delay values
are reported.
Note: Delay variation measurements smaller than 1 μs will be discarded, not
used for the sampling process, and < 0.001 will be displayed as the
minimum value. For the Current value, Not measurable is displayed when
no delay has been measured in the last second.
Thresholds button allows setting the pass/fail thresholds (refer to QoS
Metrics on page 190).