Test Setup - Test Configurator, Timer, and System
MaxTester 191
Streams - Profile
Throughput (%) check box when selected enables the throughput
pass/fail verdict and allows setting the minimum and maximum
threshold values.
Frame Loss Count/Rate check box when selected enables the Frame
Loss pass/fail verdict and allows setting the threshold of frame that are
lost.
For Count, enter the maximum count of frame that are lost before
declaring a fail verdict: 0 (default) to 9999999999.
For Rate, enter the maximum rate of frame that are lost before
declaring a fail verdict: 1.0E-14 (default) to 1.0E00.
Out-of-Sequence Count/Rate check box when selected enables the
Out-of-Sequence pass/fail verdict and allows setting the threshold of
frames that are Out-of-Sequence.
For Count, enter the maximum count of frames that are
Out-of-Sequence before declaring a fail verdict: 0 (default) to
9999999999.
For Rate, enter the maximum rate of frames that are Out-of-Sequence
before declaring a fail verdict: 1.0E-14 (default) to 1.0E00.
Jitter (ms) check box when selected enables the Jitter verdict and
allows setting the maximum Jitter in ms before declaring a fail verdict.
Latency (ms) check box when selected enables the Latency verdict
and allows setting the maximum Latency in ms before declaring a fail
verdict.