Test Control
382 MAX-800 Series
Discover Remote Button
Loop Up and Loop Down buttons
Loop Up establishes the connection with the selected remote unit
and sets the remote unit into Smart Loopback test application.
If a remote unit is in any busy status, a user confirmation is
required to proceed with the Loop Up command.
Following a successful loop up, the IP address of the remote unit
will be used as the destination IP address for the test.
Once the connection is established with the remote unit, the local
unit can be set for EtherSAM, RFC 2544, EtherBERT, or
Traffic Gen & Mon testing.
Loop Down ends the connection between the local and the
remote units.
Connect and Disconnect buttons are only available with RFC 2544,
and EtherSAM test applications.
Connect establishes the connection with the selected remote unit
and sets the remote unit into either DTS RFC 2544, or
DTS EtherSAM test application, depending on the active test on the
local unit.
If a remote unit is in any busy status, a user confirmation is
required to proceed with the Loop Up command.
Following a successful connection, the IP address of the remote
unit will be used as the destination IP address for the test.
Disconnect ends the connection between the local and the
remote units.