IN1806 and IN1808 Series Scaling Presentation Switchers • Operation 35
4. Press Enter. The display EDID is saved to the selected custom slot and assigned
to the connected inputs.
Input EDID Resolutions
Resolution 23.98 Hz 24 Hz 25 Hz 29.97 Hz 30 Hz 50 Hz 59.94 Hz 60 Hz
640x480
X
800x600
X
1024x768
X
1280x768
X
1280x800
X
1280x1024
X
1360x768
X
1366x768
X
1440x900
X
1400x1050
X
1600x900
X
1680x1050
X
1600x1200
X
1920x1200
X
480p
X X
576p
X
720p
X X X X X X
1080i
X X X
1080p
X X X X X X X X
2048x1080 (2K)
X X X X X X X X
2048x1200
X
2048x1536
X
2560x1080
X
2560x1440
X
2560x1600
X
3840x2160
X X X X X X** X** X**
4096x2160***
Automatic* Match current scaler output resolution
Custom EDID
201-210
*Default input EDID
**Rates supported only with 4:2:0 color sampling on an input in DTP or XTP mode.
4:4:4 sampling supported from DTP2 transmitters or on DisplayPort or HDMI inputs only.
***4096x2160 rates are available only for output resolution and cannot be selected for input