IN1806 and IN1808 Series Scaling Presentation Switchers • SIS Configuration and Control 52
Password Messages
If the IN1806 or IN1808 is protected by a password, the following password message
prompts you for the password to access the scaler features.
]
Password
]
The prompt requires a password, followed by a carriage return. The prompt is repeated if
the correct password is not entered.
• For initial setup: On the rear panel of the IN1806 or IN1808, a label is attached
containing the following:
The factory-configured passwords for all accounts on this device have been
set to the device serial number. Passwords are case-sensitive.
This means that, for initial setup, you must enter the serial number of your unit at the
password prompt (the serial number can be found on another label on the rear panel).
This password allows administrator level access.
If the correct password is entered, access is granted and the command prompt is
displayed. If the password is incorrect, the
]
Password
]
prompt reappears.
NOTE: Performing a unit factory reset (entering a ZQQQ SIS command or a
mode 5 reset via the rear panel Reset button) removes the serial number
password, leaving the unit with no password.
• After a password change: After the initial access, you can keep the serial number
password or change it. You can also set administrator and user level passwords (see
the Passwords SIS commands on page 84).
When you enter the new password correctly, the unit responds with one of the
following, depending on the password entered:
•
]
Login Administrator
]
•
]
Login User
]
(If the password is not accepted, the Password prompt reappears.)
The Login Administrator response represents administrator level access, while the
Login User response represents user level access. If the passwords are the same for both
administrator and user, the unit defaults to administrator privileges.
If the unit is not password-protected, it is ready to accept SIS commands immediately after
it sends the copyright message.
Scaler-initiated Messages
When certain local events occur, such as a change in the status of a contact closure port,
the scaler responds by sending a message to the host. No response is required from the
host. The following messages may be sent:
• Reconfig
]
A change in the current input frequency was detected.
• HplgO
X@
*
X7)]
A hot plug event was detected on output
X@
.
For
X7)
: 1 = assertion, 2 = de-assertion
• HdcpI
X!
*
X4$]
A change was detected in the HDCP status of input
X!
.
• HdcpO
X@
*
X4$]
A change was detected in the HDCP status of output
X@
.
• IN00•
X5!
*...*
X5!]
This message appears when a sync change (detected or
removed) occurs on any input.
X5!
is the video signal status for each input. For
X5!
, 0 = no input signal detected,
1 = input signal detected.