IN1806 and IN1808 Series Scaling Presentation Switchers • SIS Configuration and Control 84
Command ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
IP Control Port Commands (continued)
IP Setup (continued)
Query the number of open
connections
E
CC
} X8^]
Verbose modes 2 and 3:
Icc
X8^]
View the number of open connections.
Reboot networking
E
2BOOT
}
Boot2
]
Restart the network after IP setting or
DHCP changes.
Set unit name
EX8!
CN
}
Ipn•
X8!]
Assign a name for the unit.
Set unit name to factory
default
E
•CN
}
Ipn•
X9@]
Reset the unit name to its factory default
name.
View unit name
E
CN
} X8!]
View current unit name
X8!
.
KEY:
X8!
= Unit name
A text string of up to 32 characters.
• A-Z, 0-9, and the hyphen (–) are permitted.
• The first character must be a letter.
• The last character cannot be a hyphen.
• No distinction is made between uppercase and lowercase letters.
• Space or blank characters are not permitted.
X8^
= Number of open connections
0-<maximum number of open connections>
X9@
= Default unit name
Combination of the model name and the last three hexadecimal
character pairs of the unit MAC address.
Example: IN1808-IPCP-SA-14-9A-B0.
Passwords
NOTE: The initial password set at the factory is the serial number of the unit. However, if the unit is reset (via the ZQQQ SIS
command or the rear panel Reset button), this password is removed.
Set administrator password
EX9!
CA
}
Ipa•
X9!]
Set the administrator password to
X9!
.
View administrator password
E
CA
}
****
]
or
]
In verbose modes 2 and 3:
Ipa•****
]
or Ipa
]
View the administrator password.
Reset (clear) administrator
password
E
•CA
}
Ipa•
]
Reset or clear the administrator
password.
Set user password
EX9!
CU
}
Ipu•
X9!]
Set the user password.
View user password
E
CU
}
****
]
or
]
In verbose modes 2 and 3:
Ipu•****
]
or Ipu
]
View the user password. If there is
a valid password, the response is
****
]
. If there is no password, the
response is
]
.
Reset (clear) user password
E
•CU
}
Ipu•
]
Reset or clear the user password.
KEY:
X9!
= Password
• The original factory configured passwords for all accounts on this
device have been set to the device serial number. If the unit is reset to
factory settings, this password is set to no password.
• Length is 1-128 characters.
• All human-readable characters are permitted except
|
.
• The password cannot be a single space.
• Passwords are case-sensitive.
• If the admin password is cleared, the user password is cleared also.
NOTE: A user password cannot be assigned if no administrative password exists. An E14 error code is returned.