XTP CrossPoint Series • Programming Guide 101
Command Function
SIS Command
(Host to Unit to Endpoint)
Response
(Endpoint to Unit to Host)
Additional Description
XTP T VGA transmitter commands (continued)
Horizontal shift
Specify a value
E
I
X^
*
X3@
HCTR
}
HctrI
X^
*
X3@]
Set the horizontal location of first active
pixel in input
X^
.
Increment value
E
I
X^
–HCTR
}
HctrI
X^
*
X3@]
Increase the value by one pixel (shift the
image to the right).
Decrement value
E
I
X^
+HCTR
}
HctrI
X^
*
X3@]
Decrease the value by one pixel (shift
the image to the left).
View
E
I
X^
HCTR
} X3@]
Show the horizontal location of first
active pixel in input
X^
.
Vertical shift
Specify a value
E
I
X^
*
X3@
VCTR
}
VctrI
X^
*
X3@]
Set the vertical location of first active
pixel in input
X^
.
Increment value
E
I
X^
+VCTR
}
VctrI
X^
*
X3@]
Increase the value by one line (shift up).
Decrement value
E
I
X^
–VCTR
}
VctrI
X^
*
X3@]
Decrease the value by one line (shift down).
View
E
I
X^
VCTR
} X3@]
Show the vertical location of first active
pixel in input
X^
.
Save and recall analog input presets
NOTES:
Analog input presets are available for analog (RGB, YUVp, YUVi, S-video, composite) video input signals on an XTP CP 4i VGA
universal analog input board only.
Analog input presets save a set of analog variables, such as: horizontal and vertical shift, pixel phase, color and tint, brightness
and contrast, and input type.
Save an analog input preset
X^
*1*
X3#
, Spr
X^
*1*
X3#]
Command character is a comma.
Recall an analog input preset
X^
*1*
X3#
. Rpr
X^
*1*
X3#]
Command character is a period.
Input sync detection
View all input connections
0LS
X%
1
X%
2
X%
3
...
X%
n
]
16 or
32 (
n
)
X%
s; each is the connection
status of an input, starting from input 1.
Example
(XTP CrossPoint 3200):
0LS
Input:
Response Status:
No input detected
Sync detected Sync detected
1 2345
6
7 8 9
1011
12
13
32
0 0 0 1 1 1 0 1 0 0 1 0 1. . .0
XTP T FB 202, XTP T FB 202 4K, XTP T UWP 202, XTP T UWP 202 4K, XTP T UWP 302,
XTP T EU 202, and XTP T MK 202 switcher commands
Audio routing selections
Enable black signal for XTP T
endpoint
E
E
X^
*1AFMT
}
AfmtE
X^
*1
]
Enable an audio only tie for the
connected XTP transmitter.
Disable black signal for XTP T
endpoint
E
E
X^
*0AFMT
}
AfmtE
X^
*0
]
Disable an audio only tie for the
connected XTP transmitter.
View black signal output status for
XTP T endpoint
E
E
X^
*AFMT
} X2@]
The black signal status of XTP
transmitter endpoint
X^
is
X2@
.
Input reports as an HDCP-authorized device
HDCP authorized device on
E
E
X^
*1HDCP
}
HdcpE
X^
*1
]
Set the input as an HDCP authorized device.
HDCP authorized device off
E
E
X^
*0HDCP
}
HdcpE
X^
*0
]
Set the input as not an HDCP
authorized device.
View HDCP authorized status
E
E
X^
HDCP
} X1@]
Show HDCP authorized device status.
NOTE: X% = Input signal status 0 = No signal detected 1 = Sync detected
X^ = Input number (for other than tie) 0116 or
32
X1@ = HDCP authorized device 0 = Off 1 = On (default)
X2@
= Enable or disable black video ties
0
= Disable
1
= Enable
X3@ = Shift 0 through 65535
X3# = Analog input preset
1 through 8