XTP CrossPoint Series • Programming Guide 119
SIS command and Response Table for IP- and Remote Port-Specific
Commands
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional Description
IP and Remote port setup commands
Set matrix name
EX6!
CN
}
Ipn
X6!]
Read matrix name (location)
E
CN
} X6!]
Reset matrix name to factory default
E
CN
}
Ipn
X6@]
Set time and date
EX6#
CT
}
Ipt
X6#]
Read time and date
E
CT
} X6$]
Set GMT offset
EX6%
CZ
}
Ipz
X6%]
In the command, the divider between
hours and minutes can be either a
colon or a period. In the response, the
divider is a colon.
Example:
E
8.3CZ
}
Ipz+08:30
]
8.3 = 8:30
Read GMT offset
E
CZ
} X6%]
Set Daylight Savings Time
EX6^
CX
}
Ipx
X6^]
Read Daylight Savings Time
E
CX
} X6^]
Set IP address
EX6&
CI
}
Ipi
X6&]
Default: 192.168.254.254
Read IP address
E
CI
} X6&]
Read hardware address
E
CH
} X6*]
Reads MAC address.
Read # of open connections
E
CC
} X6(]
Set subnet mask
EX6&
CS
}
Ips
X6&]
Default: 255.255.0.0
Read subnet mask
E
CS
} X6&]
Set gateway IP address
EX6&
CG
}
Ipg
X6&]
Default: 0.0.0.0
Read gateway IP address
E
CG
} X6&]
Set administrator password
EX7)
CA
}
Ipa****
]
Read administrator password
E
CA
}
****] or ]
If there is a valid password the
response is
****]. If there is no
password, the response is ].
Reset (clear) administrator password
E
CA
}
Ipa
]
Set user password
EX7)
CU
}
Ipu****
]
Read user password
E
CU
}
****] or ]
If there is a valid password the
response is
****]. If there is no
password, the response is ].
Reset (clear) user password
E
CU
}
Ipu
]
Set mail server, domain name
EX6&
,
X7!
,
X7)
CM
}
Ipm
X6&
,
X7!
,
X7)
,,
]
Read mail server, domain name
E
CM
}
X6&
,
X7!
,
X7)
,,
]
Set e-mail recipient
EX7#
,
X7$
CR
}
Ipr
X7#
,
X7$
,
]
This command sets the recipient. To
receive e-mail notifications, you must then
set the events that the switcher reports,
using one or more separate Set e-mail
events (EM) commands (see below).
Example:
E
72,Jsmith@folklore.netCR
}
Ipr72,Jsmith@folklore.net,
]
Read e-mail recipient
EX7#
CR
}
X7$
,
]
Set e-mail events for recipient
EX7%
,
X7#
,
X7^
,
X4%
EM
}
Ipe
X7%
,
X7#
,
X7^
,
X4%]
You must first have set an e-mail
recipient for the e-mail account number
(
X7#
), using the separate Set e-mail (CR)
command (see above).
Example:
E
I72,0,3EM
}
IpeI*72*0*3
]
E-mail account #72 (recipient #8)
(Jsmith, as set by the preceding Set
e-mail recipient command), will receive
fail/missing and fixed/restore messages
for all inputs.
Read e-mail notifications for one
account (recipient)
EX7#
,
X8$
,
X7&
EM
} X8$
,
X8$
,
X8$
, ... ,
X8$]