·216·
Installation manual
CNC 8060
CNC 8065
2.
MACHINE PARAMETERS.
(REF: 1402)
OEM machine parameters.
SIZE
Number of OEM parameters.
Possible values: From 0 to 1000.
Default value: 0.
Associated variable: (V.)MTB.SIZE
This parameter sets the number of OEM parameters that will be used.
DATA
List of OEM parameters.
This parameter shows the table of OEM parameters. The following fields must be defined
for each parameter.
VALUE
Parameter value.
Possible values: Within ±99999.9999.
Default value: 0.
If the parameter is affected by the change of units (INCHES field), the value is entered in
the table in the units selected by machine parameter INCHES.
Each parameter has its own variables for reading or modifying (if it has a write permission)
their value from the part-program, PLC or interface. The access to these parameters using
variables will be as follows.
It must be borne in mind that reading and writing these variables interrupts block preparation
affecting program execution time. If the value of the parameter is not going to be changed
during execution, it is recommended to read the MTB variables at the beginning of the
program using arithmetic parameters (local or global) and use the global ones throughout
the program.
MODE
Mode for accessing the parameter from its variable.
Possible values: Read / Write.
Default value: Read.
The access to the parameters from the variables may be read-only or read-write. Both
reading and writing interrupt block preparation.
If a read-only access has been defined, the parameter cannot be modified from its variable.
If a write access has been defined, the parameter can be modified through its variable.
The value may always be written directly into the table, regardless of the value assigned to
this field.
DATA
VALUE Value of the parameter.
MODE Mode for accessing the parameter from its variable.
INCHES The parameter is affected by the change of units.
COMMENT OEM parameter description.
(V.)MTB.P[i] Value of the OEM parameter [i].
(V.)MTB.PF[i] Value of the OEM parameter [i]. Value per 10000.
Mnemoni. Value. V. M TB .P [ i] V.M T B. PF [ i]
P0 7 V.MTB.P[0] = 7 V.MTB.PF[0] = 70000
P8 12,5 V.MTB.P[8] = 12,5 V.MTB.PF[8] = 125000