EasyManua.ls Logo

Fagor CNC 8065 - Page 286

Fagor CNC 8065
900 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
·286·
Installation manual
CNC 8060
CNC 8065
5.
CNC-PLC COMMUNICATION.
(REF: 1402)
Displaying PLC errors and messages.
PLC errors.
When activating one of the ERR marks, the CNC interrupts the execution of the part-program
and it displays a window in the middle of the screen showing the error number and its
associated text. If the error has the "Emergen" field selected, the error will open the
emergency relay of the CNC.
External inputs should be used to activate and deactivate error marks, thus preventing the
CNC from receiving those errors at every new PLC cycle scan.
Grouping the additional information text files in a single file.
PLC messages and errors can show an additional information file in text format. The PLC
allows grouping several or all these files into a single file as follows.
Defining the additional information file.
It must be a text file (extension txt) and may have any name. The information of each message
and error must be structured in the following format:
[<id>]
<text>
The <id> field, keeping the brackets, will be the code that identifies the help text inside the
file, which needs not be the same as the number of the error or message it will be associated
with. The <text> field will be the information text that may have up to 500 characters including
line feeds.
For example, the OEM.txt file will have the following structure.
Calling the texts from the PLC message or from the PLC error.
To associate the help message with a PLC message or PLC error, the "associated file" field
must be defined like <file>#<id>. The <file> field will be the path and the name of the file.
The <id> field will be the code that identifies the help text inside the file.
For example, the "associated file" will be defined as follows.
C:\CNC8070\MTB\PLC\LANG\OEM.txt#27
If the error has a file with additional information associated with it, an access icon will appear
to the right of the error number. If the error has the "Show" field selected, the CNC shows
the additional information file directly on the screen. If the "Show" field is not selected, the
additional information file will be displayed when pressing the [HELP] key or when clicking
on the icon mentioned earlier. To close the additional data window, press [ESC].