EasyManua.ls Logo

Fagor CNC 8065 - Page 687

Fagor CNC 8065
900 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation manual
CNC 8060
CNC 8065
CNC VARIABLES.
10.
(REF: 1402)
·687·
Variables associated with the status and resources of the PLC.
(V.)PLC.LO[nb]
Variable that can be read and written via program and interface.
The variable returns the execution value; reading it interrupts block preparation.
Status of PLC local digital output [nb].
Syntax.
·nb· Number of the digital output.
(V.)PLC.M[nb]
Variable that can be read and written via program and interface.
The variable returns the execution value; reading it interrupts block preparation.
Status of PLC mark [nb].
Syntax.
·nb· Mark number.
(V.)PLC.R[nb]
Variable that can be read and written via program and interface.
The variable returns the execution value; reading it interrupts block preparation.
Status of PLC register [nb].
Syntax.
·nb· Register number.
(V.)PLC.T[nb]
Variable that can be read and written from the interface and read from the program.
The variable returns the execution value; reading it interrupts block preparation.
Status of PLC timer [nb]
Syntax.
·nb· Timer number.
(V.)PLC.C[nb]
Variable that can be read and written from the interface and read from the program.
The variable returns the execution value; reading it interrupts block preparation.
Status of PLC counter [nb].
Syntax.
·nb· Counter number.
PLC MESSAGES.
(V.)PLC.MSG[msg]
Variable that can be read and written via program and interface.
The variable returns the execution value; reading it interrupts block preparation.
Status of PLC message [msg].
V.PLC.LO[3] Status of PLC local digital output ·3·.
V.PLC.M[111] Status of PLC mark ·111·.
V.PLC.R[200] Status of PLC register ·200·.
V.PLC.T[8] Status of PLC timer ·8·.
V.PLC.C[16] Status of PLC counter ·16·.