2. Fitting and pneumatic installation
213
Festo P.BECPX−CMA X−SYS−EN en 0908NH
Note
Minimum load.
A pneumatic positioning axis always requires a minimum
load. You can find these values in tables Tab.2/4 and
Tab.2/6.
If necessary, this min
imum load must be ensured through
the use of an additional weight.
For every positioning job, you have the option of specifying
the respectively existing load,
thereby adjusting the con
troller setting of the CMAX to the various loads.
Note
If the load varies from positioning job to positioning job
(e.g. due to changing workpieces) by more than 30%, the
load in the positioning job must be
adjusted to the actual
parameters.
Load for linear drives and piston rod cylinders
Determine the permissible load using Tab.2/4:
Mounting position
Maximum load Minimum load
horizontal (á = 0°) m
max
0.1 * m
max
vertical (á = 90°) 0.33 * m
max
0.1 * m
max
diagonal (0° < á < 90°) (1 2/3 sin á) * m
max
0.1 * m
max
á = mounting position in [°]
m
max
= d³ * p
sys
* 0.008 (maximum load for horizontal mounting position [kg] )
d= cylinder diameter [mm]
p
sys
= supply pressure [bar]
Tab.2/4: Maximum and minimum load
Example:
Load for DNCI32 with p = 6 bar.

Table of Contents

Other manuals for Festo CPX-CMAX-C1-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CPX-CMAX-C1-1 and is the answer not in the manual?

Festo CPX-CMAX-C1-1 Specifications

General IconGeneral
BrandFesto
ModelCPX-CMAX-C1-1
CategoryController
LanguageEnglish

Related product manuals