FT-50 Fill Level Inspector Service Manual
5-8
° Dia. Missing Lid Width 1-65,000 Pulses:
Updating Constantly
Updating Last Reject
Updating Constantly
° Minimum Dia. Missing Lid 1-65,000 Pulses 55 Pulses
Counters Key 3
* Total Throughput 0-99,999,999
* Total Rejects 0-99,999,999
* Total Underfill 0-99,999,999
* Total Overfill 0-99,999,999
* Total Missing Lid 0-99,999,999
* Total Bulged End 0-99,999,999
* Total Down Can 0-99,999,999
* Total Dia. Missing Lid 0-99,999,999
* Total External Reject 0-99,999,999
* Reset All Counters Execute
° Reset Total Throughput Execute
° Reset Total Rejects Execute
° Reset Underfill Execute
° Reset Overfill Execute
° Reset Missing Lid Execute
° Reset Bulged End Execute
° Reset Down Can Execute
° Reset Dia. Missing Lid Execute
° Reset External Reject Execute
Rejector Key 4
* Rejector Status On /Off Off
* Fire Rejector On Demand Execute Off
° Rejector Pulse Width 0-250 ms 22 ms
° Reject Next Container 1-299 0
° Inspect Trig To C/l Rej 1-300 mm 500 mm
∞ Rejector Reaction Delay 1-150 25 ms
Function Group Function Name Parameter Default
3
4
Industrial Dynamics Company, Ltd. Document 40255-0600