FT-50 Fill Level Inspector Service Manual
8-24
Terminal and Conductor Damage
Terminal and conductor damage can cause intermittent open
circuits. If this occurs, try the following procedures.
1. Check all the cable connections for terminal and conductor
damage. If damaged, replace the cable.
2. Check all inspection unit and valve terminals for signs of
moisture or water deposits. If moisture is found, use filtered,
dry compressed air to dry the unit.
Note
If intermittent or erratic rejector operation continues, contact
Industrial Dynamics Customer Service for assistance.
Industrial Dynamics Company, Ltd. Document 40255-0600