flexfactory ag Quick Setup Guide and User’s anyfeed SX Series 42
Removing the feed surface:
1. Purge all parts from the anyfeed SX.
2. Turn off the power and air supply to the feeder.
3. Disconnect the I/O cable from the front of the feeder.
4. Remove the feed surface by sliding (pulling) it out of the
rear end of the feeder.
5. After the existing feed surface has been removed, clean all
residue from the exposed feed deck.
Installing the new feed surface:
6. Unpack the new feed surface.
7. Slide the new feed surface into the feed deck.
8. Retighten the screws on the side rails.
9. Turn on the power and air supply to the anyfeed SX.
6.3 RETAINER SPEED SETTINGS
The retainer (Figure 6-2) speed can be set
manually. The necessary steps are described on
the following page.
Use only non-abrasive, residue-free cleaner, such as rubbing
alcohol or window cleaner applied to a clean shop towel. Do not
spray directly onto the feed deck.
Figure 6-1 Feed deck beneath the feed
surface (no backlight shown)