4.3.3 COMMAND PARAMETERS DEFAULT VALUES
The table below shows the default values for the feeder command parameters. Whenever
the feeder’s firmware is reset, the parameters return to these default values.
Parameter
Default Value
ab[1]=3
default feed forward repetitions
ab[2]=3
default feed backward repetitions
ab[3]=3
default feed and flip forward repetitions
ab[4]=3
default feed and flip backward repetitions
ab[5]=3
default flip repetitions
ab[6]=3
default dispense repetitions
ab[7]=64
default purge repetitions
ab[8]=3
default heavy dispense repetitions
ab[17]=1
feed forward speed
ab[18]=1
feed backward speed
ab[19]=1
feed/flip forward speed
ab[20]=1
feed/flip backward speed
ab[21]=1
flip speed
ab[22]=1
dispense speed
ab[23]=1
purge speed
Table 4-4 Command Parameter Default Values