5. Apply a thin, even layer of BLUE LUBRICANT to the both sides of the poppet seat. Install the
poppet seat—such that the small hole faces toward the poppet—into the valve body. Install the
-014 O-ring into the groove to hold the poppet seat in place.
6. Apply a thin, even layer of BLUE LUBRICANT to the external threads of the valve body, and
then thread it onto the nozzle body by tightening the gland nut Leave this connection hand tight
for now.