Maintenance
Complete List of Error Messages
4
4-15
104 (DDE:FR D) Hardware relay trip occurred
105 (DDE:FR D) Inguard got impatient
106 (DDE:FR D) A/D fell asleep
107 (DDE:FR D) Inguard watchdog timeout
201 (DDE:FR D) 5725A ROM failure
202 (DDE:FR D) 5725A RAM failure
203 (DDE:FR D) 5725A EEPROM failure
204 (DDE:FR D) 5725A data bus failure
205 (DDE:FR D) 5725A CLAMPS circuit failure
206 (DDE:FR D) 5725A HVCLR circuit failure
207 (DDE:FR D) 5725A DAC failure
208 (DDE:FR D) 5725A watchdog timer fault
209 (DDE:FR D) 5725A I heatsink too hot
210 (DDE:FRS ) Output tripped to standby
211 (DDE:FR D) 5725A compliance V exceeded
212 (DDE:FRS ) 5725A compliance V exceeded
213 (DDE:FR D) 5725A +400V did not shut off
214 (DDE:FR D) 5725A -400V did not shut off
215 (DDE:FR D) 5725A V heatsink too hot
216 (DDE:FRS ) 5725A V heatsink too hot
217 (DDE:FR D) 5725A +400V supply too small
218 (DDE:FR D) 5725A +400V supply too large
219 (DDE:FR D) 5725A -400V supply too large
220 (DDE:FR D) 5725A -400V supply too small
221 (DDE:FR D) 5725A +400V supply overI
222 (DDE:FRS ) Output tripped to standby
223 (DDE:FR D) 5725A -400V supply overI
224 (DDE:FRS ) Output tripped to standby
225 (DDE:FR D) 5725A fan not working
226 (DDE:FR D) 5725A CLAMPS fault
227 (DDE:FRS ) Output tripped to standby
228 (DDE:FR D) 5725A software TRAP
229 (DDE:FR D) 5725A cable was off
230 (DDE:FR D) 5725A RESET
231 (DDE:FR D) 5725A guard-crossing timeout
232 (DDE:FR D) 5725A illegal command
233 (DDE:FR D) 5725A non-maskable interrupt
234 (DDE:FR D) 5725A HVCLEAR tripped
235 (DDE:FRS ) Output tripped to standby
300 (DDE: ) Invalid procedure number
301 (DDE: ) No such step in procedure
302 (DDE: ) Can’t change that while busy
303 (DDE: ) Can’t begin/resume cal there
304 (DDE: ) Wrong unit for reference
305 (DDE: ) Entered value out of bounds
306 (DDE: ) Not waiting for a reference
307 (DDE: ) Continue command ignored
308 (DDE:FR ) Cal constant outside limits
309 (DDE:FR ) Cal try to null failed
310 (DDE:FR D) Sequence failed during cal
311 (DDE:FR D) A/D measurement failed
312 (DDE:FR ) Invalid cal step parameter
313 (DDE: ) Cal switch must be ENABLED
314 (DDE:FR ) Divide by zero encountered
315 (DDE:FR ) Must be in OPER at this step