5700A/5720A Series II
Operators Manual
5-2
5-30. Reading the ESR and ESE ........................................................... 5-50
5-31. Loading the ESE .......................................................................... 5-50
5-32. Instrument Status Register................................................................ 5-51
5-33. Instrument Status Change Register................................................... 5-51
5-34. Instrument Status Change Enable Register ...................................... 5-51
5-35. Bit Assignments for the ISR, ISCR, and ISCE ............................ 5-51
5-36. Reading the ISR, ISCR, or ISCE ................................................. 5-52
5-37. Loading the ISCE......................................................................... 5-52
5-38. Fault Queue ...................................................................................... 5-53
5-39. IEEE-488 Interface Configuration........................................................ 5-54
5-40. Bus Communication Overview............................................................. 5-55
5-41. Definition: Queries and Commands ................................................. 5-56
5-42. Functional Elements Of Commands................................................. 5-56
5-43. Interface Messages ........................................................................... 5-58
5-44. The IEEE-488 Connector...................................................................... 5-60
5-45. Remote Program Examples................................................................... 5-61
5-46. Printing Main Output Calibration Shift Results ............................... 5-61
5-47. Verifying a Meter ............................................................................. 5-62
5-48. Remote Calibration........................................................................... 5-62
5-49. DC Zeros ...................................................................................... 5-62
5-50. Calibration.................................................................................... 5-63
5-51. Calibration Check ........................................................................ 5-64
5-52. Wideband AC Module (Option 5700A-03) Gain Calibration...... 5-65
5-53. Using *OPC?, *OPC, and *WAI ..................................................... 5-66
5-54. Writing an SRQ and Fault Handler .................................................. 5-67
5-55. Emulating a Fluke 5100B or 5200A Calibrator.................................... 5-68
5-56. Entering Emulation Mode ................................................................ 5-68
5-57. Exiting Emulation Mode .................................................................. 5-69
5-58. The 5720’s Display During Emulation............................................. 5-69
5-59. 5100B Emulation .................................................................................. 5-69
5-60. Local-to-Remote Transitions............................................................ 5-69
5-61. Current Output Location................................................................... 5-70
5-62. Differences in the 5700A/5720A Series II and
5100B Ohms Function.................................................................... 5-70
5-63. Ohms Remote Program Modifications for 5100B Emulation .......... 5-71
5-64. 5200A Emulation.................................................................................. 5-72
5-65. Local-to-Remote Transitions............................................................ 5-72
5-66. Voltage and Frequency Ranges ........................................................ 5-72
5-67. Rounding Numeric Entries ............................................................... 5-73
5-68. Settling Times................................................................................... 5-73
5-69. Programming External Sensing ........................................................ 5-74
5-70. Overload Conditions......................................................................... 5-74
5-71. Phase Lock Errors............................................................................. 5-74

Table of Contents

Other manuals for Fluke 5700A Series II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 5700A Series II and is the answer not in the manual?

Fluke 5700A Series II Specifications

General IconGeneral
TypeMultifunction Calibrator
Operating Temperature0 °C to 50 °C
Storage Temperature-20 °C to 70 °C
Voltage Range0 to 1100 V
DC Voltage Range10 μV to 1100 V
Frequency Range1 MHz
Humiditynon-condensing
Power Requirements100 V to 240 V